Concerning the slow raid:
Kyle, We will track this issue under Ticket: #15298. It looks like the most recent storage server purchase you made was under order #S2025934 [SM24266, SM24267] for 2 x K300s. We may have seen the issue you are describing to us before. The internal host drives have a feature where if there is too much vibration in the server the write speeds will slow way down in order to prevent damage to the platters. With these storage servers you would notice this issue if the server rack is vibrating more than usual or if the exhaust fans in the rear of the chassis are causing too much vibration. I would like to target the fans first. If you are able to, please install lm_sensors on one of the storage servers and send us the fan speed output. This will allow us to narrow it down to which version of the exhaust fans your servers have in the rear of the chassis. Thanks in advance, Jonathan McQuistion Silicon Mechanics Support